# WaterTAP Copyright (c) 2021, The Regents of the University of California,
# through Lawrence Berkeley National Laboratory, Oak Ridge National
# Laboratory, National Renewable Energy Laboratory, and National Energy
# Technology Laboratory (subject to receipt of any required approvals from
# the U.S. Dept. of Energy). All rights reserved.
#
# Please see the files COPYRIGHT.md and LICENSE.md for full copyright and license
# information, respectively. These files are also available online at the URL
# "https://github.com/watertap-org/watertap/"
#
###############################################################################
import itertools
from pyomo.environ import (
ConcreteModel,
value,
Param,
Var,
Constraint,
Expression,
Objective,
TransformationFactory,
Block,
NonNegativeReals,
RangeSet,
Set,
check_optimal_termination,
units as pyunits,
)
from pyomo.network import Arc, SequentialDecomposition
from pyomo.util.check_units import assert_units_consistent
from idaes.core import FlowsheetBlock, UnitModelCostingBlock
from idaes.core.solvers import get_solver
from idaes.core.util.exceptions import InitializationError
from idaes.core.util.initialization import propagate_state
from idaes.core.util.misc import StrEnum
from idaes.models.unit_models import Feed, Product, Mixer
from idaes.models.unit_models.mixer import MomentumMixingType
import idaes.core.util.scaling as iscale
import idaes.logger as idaeslogger
from watertap.unit_models.reverse_osmosis_1D import (
ReverseOsmosis1D,
ConcentrationPolarizationType,
MassTransferCoefficient,
PressureChangeType,
)
from watertap.unit_models.pressure_changer import Pump, EnergyRecoveryDevice
from watertap.core.util.initialization import (
assert_no_degrees_of_freedom,
assert_degrees_of_freedom,
)
from watertap.costing.watertap_costing_package import (
WaterTAPCosting,
make_capital_cost_var,
)
import watertap.property_models.NaCl_prop_pack as props
[docs]class ACase(StrEnum):
fixed = "fixed"
optimize = "optimize"
single_optimum = "single_optimum"
[docs]class BCase(StrEnum):
single_optimum = "single_optimum"
optimize = "optimize"
[docs]class ABTradeoff(StrEnum):
inequality_constraint = "inequality_constraint"
equality_constraint = "equality_constraint"
none = "none"
def run_lsrro_case(
number_of_stages,
water_recovery=None,
Cin=None,
Cbrine=None,
A_case=ACase.fixed,
B_case=BCase.optimize,
AB_tradeoff=ABTradeoff.none,
A_value=None,
has_NaCl_solubility_limit=None,
has_calculated_concentration_polarization=None,
has_calculated_ro_pressure_drop=None,
permeate_quality_limit=None,
AB_gamma_factor=None,
B_max=None,
number_of_RO_finite_elements=10,
):
m = build(
number_of_stages,
has_NaCl_solubility_limit,
has_calculated_concentration_polarization,
has_calculated_ro_pressure_drop,
number_of_RO_finite_elements,
B_max,
)
set_operating_conditions(m, Cin)
initialize(m)
solve(m)
print("\n***---Simulation results---***")
display_system(m)
display_design(m)
display_state(m)
optimize_set_up(
m,
water_recovery,
Cbrine,
A_case,
B_case,
AB_tradeoff,
A_value,
permeate_quality_limit,
AB_gamma_factor,
B_max,
)
res = solve(m, raise_on_failure=False, tee=False)
print("\n***---Optimization results---***")
if check_optimal_termination(res):
display_system(m)
display_design(m)
display_state(m)
display_RO_reports(m)
return m, res
def build(
number_of_stages=2,
has_NaCl_solubility_limit=True,
has_calculated_concentration_polarization=True,
has_calculated_ro_pressure_drop=True,
number_of_RO_finite_elements=10,
B_max=None,
):
# ---building model---
m = ConcreteModel()
m.fs = FlowsheetBlock(dynamic=False)
m.fs.properties = props.NaClParameterBlock()
m.fs.costing = WaterTAPCosting()
# explicitly set the costing parameters used
m.fs.costing.utilization_factor.fix(0.9)
m.fs.costing.factor_total_investment.fix(2)
m.fs.costing.factor_maintenance_labor_chemical.fix(0.03)
m.fs.costing.factor_capital_annualization.fix(0.1)
m.fs.costing.electricity_base_cost.set_value(0.07)
m.fs.costing.reverse_osmosis.factor_membrane_replacement.fix(0.15)
m.fs.costing.reverse_osmosis.membrane_cost.fix(30)
m.fs.costing.reverse_osmosis.high_pressure_membrane_cost.fix(50)
m.fs.costing.high_pressure_pump.cost.fix(53 / 1e5 * 3600)
m.fs.costing.energy_recovery_device.pressure_exchanger_cost.fix(535)
m.fs.NumberOfStages = Param(initialize=number_of_stages)
m.fs.Stages = RangeSet(m.fs.NumberOfStages)
m.fs.LSRRO_Stages = RangeSet(2, m.fs.NumberOfStages)
m.fs.NonFinalStages = RangeSet(m.fs.NumberOfStages - 1)
if number_of_stages > 1:
m.fs.IntermediateStages = RangeSet(2, m.fs.NumberOfStages - 1)
else:
m.fs.IntermediateStages = RangeSet(0)
m.fs.FirstStage = m.fs.Stages.first()
m.fs.LastStage = m.fs.Stages.last()
m.fs.feed = Feed(property_package=m.fs.properties)
m.fs.product = Product(property_package=m.fs.properties)
m.fs.disposal = Product(property_package=m.fs.properties)
# Add the mixers
m.fs.Mixers = Mixer(
m.fs.NonFinalStages,
property_package=m.fs.properties,
momentum_mixing_type=MomentumMixingType.equality,
inlet_list=["upstream", "downstream"],
)
# Add the pumps
m.fs.PrimaryPumps = Pump(m.fs.Stages, property_package=m.fs.properties)
for pump in m.fs.PrimaryPumps.values():
pump.costing = UnitModelCostingBlock(
flowsheet_costing_block=m.fs.costing,
costing_method=cost_high_pressure_pump_lsrro,
)
# Add the equalizer pumps
m.fs.BoosterPumps = Pump(m.fs.LSRRO_Stages, property_package=m.fs.properties)
for pump in m.fs.BoosterPumps.values():
pump.costing = UnitModelCostingBlock(
flowsheet_costing_block=m.fs.costing,
costing_method=cost_high_pressure_pump_lsrro,
)
m.fs.total_pump_work = Expression(
expr=sum(
pyunits.convert(pump.work_mechanical[0], to_units=pyunits.kW)
for pump in itertools.chain(
m.fs.PrimaryPumps.values(), m.fs.BoosterPumps.values()
)
)
)
# Add the stages ROs
if has_calculated_ro_pressure_drop:
pressure_change_type = PressureChangeType.calculated
else:
pressure_change_type = PressureChangeType.fixed_per_stage
if has_calculated_concentration_polarization:
cp_type = ConcentrationPolarizationType.calculated
kf_type = MassTransferCoefficient.calculated
else:
cp_type = ConcentrationPolarizationType.none
kf_type = MassTransferCoefficient.none
m.fs.ROUnits = ReverseOsmosis1D(
m.fs.Stages,
property_package=m.fs.properties,
has_pressure_change=has_calculated_ro_pressure_drop,
pressure_change_type=pressure_change_type,
mass_transfer_coefficient=kf_type,
concentration_polarization_type=cp_type,
transformation_scheme="BACKWARD",
transformation_method="dae.finite_difference",
finite_elements=number_of_RO_finite_elements,
has_full_reporting=True,
)
for idx, ro_stage in m.fs.ROUnits.items():
if idx == m.fs.FirstStage:
ro_stage.costing = UnitModelCostingBlock(
flowsheet_costing_block=m.fs.costing,
costing_method_arguments={"ro_type": "standard"},
)
else:
ro_stage.costing = UnitModelCostingBlock(
flowsheet_costing_block=m.fs.costing,
costing_method_arguments={"ro_type": "high_pressure"},
)
# Add EnergyRecoveryDevices
m.fs.EnergyRecoveryDeviceSet = Set(
initialize=[m.fs.FirstStage, m.fs.LastStage]
if m.fs.FirstStage < m.fs.LastStage
else [m.fs.LastStage]
)
m.fs.EnergyRecoveryDevices = EnergyRecoveryDevice(
m.fs.EnergyRecoveryDeviceSet, property_package=m.fs.properties
)
for erd in m.fs.EnergyRecoveryDevices.values():
erd.costing = UnitModelCostingBlock(
flowsheet_costing_block=m.fs.costing,
costing_method_arguments={
"energy_recovery_device_type": "pressure_exchanger"
},
)
m.fs.recovered_pump_work = Expression(
expr=sum(
pyunits.convert(erd.work_mechanical[0], to_units=pyunits.kW)
for erd in m.fs.EnergyRecoveryDevices.values()
)
)
m.fs.net_pump_work = Expression(
expr=m.fs.total_pump_work + m.fs.recovered_pump_work
)
# additional parameters, variables or expressions ---------------------------------------------------------------------------
m.fs.ro_min_pressure = Param(initialize=10e5, units=pyunits.Pa, mutable=True)
m.fs.lsrro_min_pressure = Param(initialize=10e5, units=pyunits.Pa, mutable=True)
m.fs.ro_max_pressure = Param(initialize=85e5, units=pyunits.Pa, mutable=True)
m.fs.lsrro_max_pressure = Param(initialize=65e5, units=pyunits.Pa, mutable=True)
if B_max is not None:
m.fs.B_max = Param(initialize=B_max, mutable=True, units=pyunits.m / pyunits.s)
# system water recovery
m.fs.water_recovery = Var(
initialize=0.5,
bounds=(0, 1),
domain=NonNegativeReals,
units=pyunits.dimensionless,
doc="System Water Recovery",
)
m.fs.eq_water_recovery = Constraint(
expr=m.fs.feed.properties[0].flow_vol * m.fs.water_recovery
== m.fs.product.properties[0].flow_vol
)
# costing and summary quantities
m.fs.costing.cost_process()
product_flow_vol_total = m.fs.product.properties[0].flow_vol
m.fs.costing.add_annual_water_production(product_flow_vol_total)
m.fs.costing.add_specific_energy_consumption(product_flow_vol_total)
m.fs.costing.add_LCOW(product_flow_vol_total)
# objective
m.fs.objective = Objective(expr=m.fs.costing.LCOW)
# Expressions for parameter sweep -----------------------------------------
# Final permeate concentration as mass fraction
m.fs.product.properties[0].mass_frac_phase_comp
# Touch feed concentration as mass concentration
m.fs.feed.properties[0].conc_mass_phase_comp
# Touch final brine concentration as mass concentration
m.fs.disposal.properties[0].conc_mass_phase_comp
# Touch final brine concentration as mass fraction
m.fs.disposal.properties[0].mass_frac_phase_comp
m.fs.mass_water_recovery = Expression(
expr=m.fs.product.flow_mass_phase_comp[0, "Liq", "H2O"]
/ m.fs.feed.flow_mass_phase_comp[0, "Liq", "H2O"]
)
m.fs.system_salt_rejection = Expression(
expr=1
- m.fs.product.properties[0].conc_mass_phase_comp["Liq", "NaCl"]
/ m.fs.feed.properties[0].conc_mass_phase_comp["Liq", "NaCl"]
)
m.fs.annual_feed = Expression(
expr=pyunits.convert(
m.fs.feed.properties[0].flow_vol, to_units=pyunits.m**3 / pyunits.year
)
* m.fs.costing.utilization_factor
)
m.fs.final_permeate_concentration = Expression(
expr=m.fs.product.flow_mass_phase_comp[0, "Liq", "NaCl"]
/ sum(m.fs.product.flow_mass_phase_comp[0, "Liq", j] for j in ["H2O", "NaCl"])
)
m.fs.costing.add_LCOW(m.fs.feed.properties[0].flow_vol, name="LCOW_feed")
m.fs.costing.add_specific_energy_consumption(
m.fs.feed.properties[0].flow_vol, name="specific_energy_consumption_feed"
)
@m.fs.Expression(m.fs.Stages)
def stage_recovery_vol(fs, stage):
return (
fs.ROUnits[stage].mixed_permeate[0].flow_vol
/ fs.PrimaryPumps[stage].control_volume.properties_in[0].flow_vol
)
@m.fs.Expression(m.fs.Stages)
def stage_recovery_mass_H2O(fs, stage):
return (
fs.ROUnits[stage].mixed_permeate[0].flow_mass_phase_comp["Liq", "H2O"]
/ m.fs.PrimaryPumps[stage]
.control_volume.properties_in[0]
.flow_mass_phase_comp["Liq", "H2O"]
)
m.fs.costing.primary_pump_capex_lcow = Expression(
expr=m.fs.costing.factor_capital_annualization
* sum(m.fs.PrimaryPumps[n].costing.capital_cost for n in m.fs.Stages)
/ m.fs.costing.annual_water_production
)
m.fs.total_membrane_area = Expression(
expr=sum(ro.area for ro in m.fs.ROUnits.values())
)
m.fs.costing.booster_pump_capex_lcow = Expression(
expr=m.fs.costing.factor_capital_annualization
* (
sum(m.fs.BoosterPumps[n].costing.capital_cost for n in m.fs.LSRRO_Stages)
if number_of_stages > 1
else 0 * m.fs.costing.base_currency
)
/ m.fs.costing.annual_water_production,
)
m.fs.costing.erd_capex_lcow = Expression(
expr=m.fs.costing.factor_capital_annualization
* sum(erd.costing.capital_cost for erd in m.fs.EnergyRecoveryDevices.values())
/ m.fs.costing.annual_water_production
)
m.fs.costing.electricity_lcow = Expression(
expr=m.fs.costing.aggregate_flow_costs["electricity"]
* m.fs.costing.utilization_factor
/ m.fs.costing.annual_water_production
)
m.fs.costing.pumping_energy_aggregate_lcow = Expression(
expr=m.fs.costing.factor_total_investment
* (
m.fs.costing.primary_pump_capex_lcow
+ (
m.fs.costing.booster_pump_capex_lcow
if number_of_stages > 1
else 0 * m.fs.costing.base_currency
)
+ m.fs.costing.erd_capex_lcow
)
* (
1
+ m.fs.costing.factor_maintenance_labor_chemical
/ m.fs.costing.factor_capital_annualization
)
+ m.fs.costing.electricity_lcow
)
m.fs.costing.membrane_capex_lcow = Expression(
expr=m.fs.costing.factor_capital_annualization
* sum(m.fs.ROUnits[n].costing.capital_cost for n in m.fs.Stages)
/ m.fs.costing.annual_water_production
)
m.fs.costing.indirect_capex_lcow = Expression(
expr=m.fs.costing.factor_capital_annualization
* (m.fs.costing.total_investment_cost - m.fs.costing.total_capital_cost)
/ m.fs.costing.annual_water_production
)
m.fs.costing.membrane_replacement_lcow = Expression(
expr=sum(m.fs.ROUnits[n].costing.fixed_operating_cost for n in m.fs.Stages)
/ m.fs.costing.annual_water_production
)
m.fs.costing.chemical_labor_maintenance_lcow = Expression(
expr=m.fs.costing.maintenance_labor_chemical_operating_cost
/ m.fs.costing.annual_water_production
)
m.fs.costing.membrane_aggregate_lcow = Expression(
expr=m.fs.costing.factor_total_investment
* m.fs.costing.membrane_capex_lcow
* (
1
+ m.fs.costing.factor_maintenance_labor_chemical
/ m.fs.costing.factor_capital_annualization
)
+ m.fs.costing.membrane_replacement_lcow
)
# Connections ------------------------------------------------------------
# Connect the feed to the first pump
m.fs.feed_to_pump = Arc(
source=m.fs.feed.outlet, destination=m.fs.PrimaryPumps[1].inlet
)
# Connect the primary RO permeate to the product
m.fs.primary_RO_to_product = Arc(
source=m.fs.ROUnits[1].permeate, destination=m.fs.product.inlet
)
# Connect the Pump n to the Mixer n
m.fs.pump_to_mixer = Arc(
m.fs.NonFinalStages,
rule=lambda fs, n: {
"source": fs.PrimaryPumps[n].outlet,
"destination": fs.Mixers[n].upstream,
},
)
# Connect the Mixer n to the Stage n
m.fs.mixer_to_stage = Arc(
m.fs.NonFinalStages,
rule=lambda fs, n: {
"source": fs.Mixers[n].outlet,
"destination": fs.ROUnits[n].inlet,
},
)
# Connect the Stage n to the Eq Pump n
m.fs.stage_permeate_to_booster_pump = Arc(
m.fs.LSRRO_Stages,
rule=lambda fs, n: {
"source": fs.ROUnits[n].permeate,
"destination": fs.BoosterPumps[n].inlet,
},
)
# Connect the Eq Pump n to the Mixer n-1
m.fs.booster_pump_to_mixer = Arc(
m.fs.LSRRO_Stages,
rule=lambda fs, n: {
"source": fs.BoosterPumps[n].outlet,
"destination": fs.Mixers[n - 1].downstream,
},
)
last_stage = m.fs.LastStage
if number_of_stages > 1:
# Connect the primary RO permeate to the product
m.fs.primary_RO_to_erd = Arc(
source=m.fs.ROUnits[1].retentate,
destination=m.fs.EnergyRecoveryDevices[1].inlet,
)
# Connect 1st stage ERD to primary pump
m.fs.primary_ERD_to_pump = Arc(
source=m.fs.EnergyRecoveryDevices[1].outlet,
destination=m.fs.PrimaryPumps[2].inlet,
)
# Connect the Stage n to the Pump n+1
m.fs.stage_retentate_to_pump = Arc(
m.fs.IntermediateStages,
rule=lambda fs, n: {
"source": fs.ROUnits[n].retentate,
"destination": fs.PrimaryPumps[n + 1].inlet,
},
)
# Connect the Pump N to the Stage N
m.fs.pumpN_to_stageN = Arc(
source=m.fs.PrimaryPumps[last_stage].outlet,
destination=m.fs.ROUnits[last_stage].inlet,
)
# Connect Final Stage to EnergyRecoveryDevice Pump
m.fs.stage_to_erd = Arc(
source=m.fs.ROUnits[last_stage].retentate,
destination=m.fs.EnergyRecoveryDevices[last_stage].inlet,
)
# Connect the EnergyRecoveryDevice to the disposal
m.fs.erd_to_disposal = Arc(
source=m.fs.EnergyRecoveryDevices[last_stage].outlet,
destination=m.fs.disposal.inlet,
)
# additional bounding
if has_NaCl_solubility_limit:
for b in m.component_data_objects(Block, descend_into=True):
# NaCl solubility limit
if hasattr(b, "is_property_constructed") and b.is_property_constructed(
"mass_frac_phase_comp"
):
b.mass_frac_phase_comp["Liq", "NaCl"].setub(0.2614)
TransformationFactory("network.expand_arcs").apply_to(m)
return m
def cost_high_pressure_pump_lsrro(blk, cost_electricity_flow=True):
t0 = blk.flowsheet().time.first()
make_capital_cost_var(blk)
blk.capital_cost_constraint = Constraint(
expr=blk.capital_cost
== blk.costing_package.high_pressure_pump.cost
* pyunits.watt
/ (pyunits.m**3 * pyunits.pascal / pyunits.s)
* blk.unit_model.outlet.pressure[t0]
* blk.unit_model.control_volume.properties_out[t0].flow_vol
)
if cost_electricity_flow:
blk.costing_package.cost_flow(
pyunits.convert(blk.unit_model.work_mechanical[t0], to_units=pyunits.kW),
"electricity",
)
def set_operating_conditions(m, Cin=None):
# ---specifications---
# parameters
pump_efi = 0.75 # pump efficiency [-]
erd_efi = 0.8 # energy recovery device efficiency [-]
mem_A = 4.2e-12 # membrane water permeability coefficient [m/s-Pa]
mem_B = 3.5e-8 # membrane salt permeability coefficient [m/s]
height = 1e-3 # channel height in membrane stage [m]
spacer_porosity = 0.85 # spacer porosity in membrane stage [-]
width = 5 # effective membrane width [m]
area = 100 # membrane area [m^2]
pressure_atm = 101325 # atmospheric pressure [Pa]
# feed
# feed_flow_mass = 1*pyunits.kg/pyunits.s
if Cin is None:
Cin = 70
feed_temperature = 273.15 + 20
# initialize feed
m.fs.feed.pressure[0].fix(pressure_atm)
m.fs.feed.temperature[0].fix(feed_temperature)
m.fs.feed.properties[0].conc_mass_phase_comp["Liq", "NaCl"] = Cin
m.fs.feed.properties.calculate_state(
var_args={
("conc_mass_phase_comp", ("Liq", "NaCl")): value(
m.fs.feed.properties[0].conc_mass_phase_comp["Liq", "NaCl"]
), # feed mass concentration
("flow_vol_phase", "Liq"): 1e-3,
}, # volumetric feed flowrate [-]
hold_state=True, # fixes the calculated component mass flow rates
)
# initialize pumps
for pump in m.fs.PrimaryPumps.values():
pump.control_volume.properties_out[0].pressure = 75e5
pump.efficiency_pump.fix(pump_efi)
pump.control_volume.properties_out[0].pressure.fix()
iscale.set_scaling_factor(pump.control_volume.work, 1e-3)
# initialize eq pumps
for pump in m.fs.BoosterPumps.values():
pump.efficiency_pump.fix(pump_efi)
iscale.set_scaling_factor(pump.control_volume.work, 1e-3)
# initialize stages
for idx, stage in m.fs.ROUnits.items():
if idx == m.fs.FirstStage:
B_scale = 1.0
else:
B_scale = 100.0
stage.A_comp.fix(mem_A)
stage.B_comp.fix(mem_B * B_scale)
stage.area.fix(area / float(idx))
stage.width.fix(width)
stage.mixed_permeate[0].pressure.fix(pressure_atm)
if (
stage.config.mass_transfer_coefficient == MassTransferCoefficient.calculated
) or stage.config.pressure_change_type == PressureChangeType.calculated:
stage.channel_height.fix(height)
stage.spacer_porosity.fix(spacer_porosity)
# energy recovery devices
for erd in m.fs.EnergyRecoveryDevices.values():
erd.efficiency_pump.fix(erd_efi)
iscale.set_scaling_factor(erd.control_volume.work, 1e-3)
# if FirstStage *is* LastStage, we'll just overwrite the pressure
m.fs.EnergyRecoveryDevices[m.fs.FirstStage].control_volume.properties_out[
0
].pressure.fix(70e5)
m.fs.EnergyRecoveryDevices[m.fs.LastStage].control_volume.properties_out[
0
].pressure.fix(pressure_atm)
# ---scaling---
m.fs.properties.set_default_scaling("flow_mass_phase_comp", 1, index=("Liq", "H2O"))
m.fs.properties.set_default_scaling(
"flow_mass_phase_comp", 1e2, index=("Liq", "NaCl")
)
iscale.calculate_scaling_factors(m)
# ---checking model---
assert_units_consistent(m)
assert_no_degrees_of_freedom(m)
print(
"Feed Concentration = %.1f ppt"
% (value(m.fs.feed.flow_mass_phase_comp[0, "Liq", "NaCl"]) * 1000)
)
def _lsrro_mixer_guess_initializer(
mixer, solvent_multiplier, solute_multiplier, optarg
):
for vname in mixer.upstream.vars:
if vname == "flow_mass_phase_comp":
for time, phase, comp in mixer.upstream.vars[vname]:
if comp in mixer.config.property_package.solute_set:
mixer.downstream.vars[vname][time, phase, comp].value = (
solute_multiplier
* mixer.upstream.vars[vname][time, phase, comp].value
)
elif comp in mixer.config.property_package.solvent_set:
mixer.downstream.vars[vname][time, phase, comp].value = (
solvent_multiplier
* mixer.upstream.vars[vname][time, phase, comp].value
)
else:
raise RuntimeError(f"Unknown component {comp}")
else: # copy the state
for idx in mixer.upstream.vars[vname]:
mixer.downstream.vars[vname][idx].value = mixer.upstream.vars[vname][
idx
].value
mixer.initialize(optarg=optarg)
def do_forward_initialization_pass(m, optarg, guess_mixers):
print("--------------------START FORWARD INITIALIZATION PASS--------------------")
# start with the feed
m.fs.feed.initialize(optarg=optarg)
propagate_state(m.fs.feed_to_pump)
last_stage = m.fs.LastStage
first_stage = m.fs.FirstStage
for stage in m.fs.Stages:
m.fs.PrimaryPumps[stage].initialize(optarg=optarg)
if stage == last_stage:
propagate_state(m.fs.pumpN_to_stageN)
else:
propagate_state(m.fs.pump_to_mixer[stage])
if guess_mixers:
_lsrro_mixer_guess_initializer(
m.fs.Mixers[stage],
solvent_multiplier=0.5,
solute_multiplier=0.2,
optarg=optarg,
)
else:
m.fs.Mixers[stage].initialize(optarg=optarg)
propagate_state(m.fs.mixer_to_stage[stage])
m.fs.ROUnits[stage].initialize(optarg=optarg, raise_on_failure=False)
if stage == first_stage:
propagate_state(m.fs.primary_RO_to_product)
m.fs.product.initialize(optarg=optarg)
if value(m.fs.NumberOfStages) > 1:
propagate_state(m.fs.primary_RO_to_erd)
m.fs.EnergyRecoveryDevices[first_stage].initialize(optarg=optarg)
propagate_state(m.fs.primary_ERD_to_pump)
else:
propagate_state(m.fs.stage_permeate_to_booster_pump[stage])
m.fs.BoosterPumps[stage].initialize(optarg=optarg)
propagate_state(m.fs.booster_pump_to_mixer[stage])
if stage in m.fs.IntermediateStages:
propagate_state(m.fs.stage_retentate_to_pump[stage])
# for the end stage
propagate_state(m.fs.stage_to_erd)
m.fs.EnergyRecoveryDevices[last_stage].initialize(optarg=optarg)
propagate_state(m.fs.erd_to_disposal)
m.fs.disposal.initialize(optarg=optarg)
def do_backward_initialization_pass(m, optarg):
print("--------------------START BACKWARD INITIALIZATION PASS--------------------")
first_stage = m.fs.FirstStage
for stage in reversed(m.fs.NonFinalStages):
m.fs.Mixers[stage].initialize(optarg=optarg)
propagate_state(m.fs.mixer_to_stage[stage])
m.fs.ROUnits[stage].initialize(optarg=optarg, raise_on_failure=False)
if stage == first_stage:
if value(m.fs.NumberOfStages) > 1:
propagate_state(m.fs.primary_ERD_to_pump)
m.fs.EnergyRecoveryDevices[first_stage].initialize(optarg=optarg)
propagate_state(m.fs.primary_RO_to_erd)
propagate_state(m.fs.primary_RO_to_product)
m.fs.product.initialize(optarg=optarg)
else:
propagate_state(m.fs.stage_retentate_to_pump[stage])
propagate_state(m.fs.stage_permeate_to_booster_pump[stage])
m.fs.BoosterPumps[stage].initialize(optarg=optarg)
propagate_state(m.fs.booster_pump_to_mixer[stage])
def initialize(m, verbose=True, solver=None):
# ---initializing---
# set up solvers
if solver is None:
solver = get_solver()
optarg = solver.options
do_forward_initialization_pass(m, optarg=optarg, guess_mixers=True)
for _ in range(m.fs.NumberOfStages.value // 2):
do_backward_initialization_pass(m, optarg=optarg)
do_forward_initialization_pass(m, optarg=optarg, guess_mixers=False)
# # set up SD tool
seq = SequentialDecomposition()
seq.options.tear_method = "Direct"
seq.options.iterLim = m.fs.NumberOfStages
seq.options.tear_set = list(m.fs.booster_pump_to_mixer.values())
seq.options.log_info = True
# run SD tool
def func_initialize(unit):
outlvl = idaeslogger.INFO if verbose else idaeslogger.CRITICAL
if "ROUnits" in unit.name:
unit.initialize(
optarg=solver.options, outlvl=outlvl, raise_on_failure=False
)
else:
unit.initialize(optarg=solver.options, outlvl=outlvl)
seq.run(m, func_initialize)
m.fs.costing.initialize()
def solve(model, solver=None, tee=False, raise_on_failure=False):
# ---solving---
if solver is None:
solver = get_solver()
results = solver.solve(model, tee=tee)
if check_optimal_termination(results):
return results
msg = (
"The current configuration is infeasible. Please adjust the decision variables."
)
if raise_on_failure:
raise RuntimeError(msg)
else:
print(msg)
return results
[docs]def optimize_set_up(
m,
water_recovery=None,
Cbrine=None,
A_case=ACase.fixed,
B_case=BCase.optimize,
AB_tradeoff=ABTradeoff.none,
A_value=None,
permeate_quality_limit=None,
AB_gamma_factor=None,
B_max=None,
):
"""
Get the LSRRO flowsheet ready to optimize
Attributes
----------
B_case: 'single_optimum' or anything else to optimize B value at every LSR stage
A_case: 'fixed' or 'optimize' or 'single_optimum' A at every LSR stage
AB_tradeoff: 'inequality_constraint' B >= function of A
'equality_constraint' B = function of A
'none' no constraint relating B value to A value
A_value: if A_case='fixed', then provide a value to fix A with
Returns
-------
model (Pyomo ConcreteModel) : The LSRRO flowsheet.
"""
for idx, pump in m.fs.PrimaryPumps.items():
pump.control_volume.properties_out[0].pressure.unfix()
pump.deltaP.setlb(0)
if idx > m.fs.Stages.first():
pump.max_lsrro_pressure_con = Constraint(
expr=(
m.fs.lsrro_min_pressure,
pump.control_volume.properties_out[0].pressure,
m.fs.lsrro_max_pressure,
)
)
iscale.constraint_scaling_transform(
pump.max_lsrro_pressure_con,
iscale.get_scaling_factor(
pump.control_volume.properties_out[0].pressure
),
)
else:
pump.max_ro_pressure_con = Constraint(
expr=(
m.fs.ro_min_pressure,
pump.control_volume.properties_out[0].pressure,
m.fs.ro_max_pressure,
)
)
iscale.constraint_scaling_transform(
pump.max_ro_pressure_con,
iscale.get_scaling_factor(
pump.control_volume.properties_out[0].pressure
),
)
if value(m.fs.NumberOfStages) > 1:
m.fs.EnergyRecoveryDevices[1].control_volume.properties_out[0].pressure.unfix()
m.fs.EnergyRecoveryDevices[1].deltaP.setub(0)
# unfix eq pumps
for idx, pump in m.fs.BoosterPumps.items():
pump.control_volume.properties_out[0].pressure.unfix()
pump.max_ro_pressure_con = Constraint(
expr=(
m.fs.ro_min_pressure,
pump.control_volume.properties_out[0].pressure,
m.fs.ro_max_pressure,
)
)
iscale.constraint_scaling_transform(
pump.max_ro_pressure_con,
iscale.get_scaling_factor(pump.control_volume.properties_out[0].pressure),
)
pump.deltaP.setlb(0)
if B_case == BCase.single_optimum:
m.fs.B_comp_system = Var(
domain=NonNegativeReals,
units=pyunits.m * pyunits.s**-1,
doc="Solute permeability coeff. constant in all LSR stages",
)
m.fs.B_comp_system.set_value(
m.fs.ROUnits[m.fs.LSRRO_Stages.first()].B_comp[0, "NaCl"]
)
m.fs.B_comp_system.setlb(3.5e-8)
if B_max is None:
m.fs.B_comp_system.setub(3.5e-8 * 1e2)
else:
m.fs.B_comp_system.setub(m.fs.B_max)
if A_case == ACase.single_optimum:
m.fs.A_comp_system = Var(
domain=NonNegativeReals,
units=pyunits.m * pyunits.s**-1 * pyunits.Pa**-1,
doc="Water permeability coeff. constant in all LSR stages",
)
m.fs.A_comp_system.set_value(m.fs.ROUnits[2].A_comp[0, "H2O"])
m.fs.A_comp_system.setlb(2.78e-12)
m.fs.A_comp_system.setub(4.2e-11)
if (
AB_tradeoff == ABTradeoff.equality_constraint
or AB_tradeoff == ABTradeoff.inequality_constraint
):
m.fs.AB_tradeoff_coeff = Param(initialize=0.01333, mutable=True)
m.fs.AB_tradeoff_coeff.set_value(
AB_gamma_factor * value(m.fs.AB_tradeoff_coeff)
)
# unfix stages
for idx, stage in m.fs.ROUnits.items():
stage.area.unfix()
stage.width.unfix()
stage.area.setlb(1)
stage.area.setub(20000)
stage.width.setlb(0.1)
stage.width.setub(1000)
if (
stage.config.mass_transfer_coefficient == MassTransferCoefficient.calculated
) or (stage.config.pressure_change_type == PressureChangeType.calculated):
stage.N_Re[0, 0].unfix()
if idx > m.fs.Stages.first():
stage.B_comp.unfix()
stage.B_comp.setlb(3.5e-8)
if B_max is not None:
stage.B_comp.setub(m.fs.B_max)
else:
stage.B_comp.setub(None)
if B_case == BCase.single_optimum:
stage.B_comp_equal = Constraint(
expr=stage.B_comp[0, "NaCl"] == m.fs.B_comp_system
)
if A_case == ACase.single_optimum:
stage.A_comp_equal = Constraint(
expr=stage.A_comp[0, "H2O"] == m.fs.A_comp_system
)
stage.A_min = Param(
initialize=2.78e-12, units=pyunits.m**2 / pyunits.kg * pyunits.s
)
stage.A_max = Param(
initialize=4.2e-11, units=pyunits.m**2 / pyunits.kg * pyunits.s
)
stage._A_comp_con = Constraint(
expr=(stage.A_min, stage.A_comp[0, "H2O"], stage.A_max)
)
iscale.constraint_scaling_transform(
stage._A_comp_con, iscale.get_scaling_factor(stage.A_comp[0, "H2O"])
)
if A_case == ACase.optimize or A_case == ACase.single_optimum:
stage.A_comp.unfix()
stage.A_comp.setlb(2.78e-12)
stage.A_comp.setub(4.2e-11)
elif A_case == ACase.fixed:
if not isinstance(A_value, (int, float)):
raise TypeError("A_value must be a numeric value")
stage.A_comp.unfix()
stage.A_comp.fix(A_value)
else:
raise TypeError(
f'A_case must be set to "fix", "single_optimum", "optimize" or None.'
f" A_case was set to {A_case}"
)
if AB_tradeoff == ABTradeoff.equality_constraint:
stage.ABtradeoff = Constraint(
expr=pyunits.convert(
stage.B_comp[0, "NaCl"],
to_units=pyunits.L * pyunits.m**-2 * pyunits.hour**-1,
)
== m.fs.AB_tradeoff_coeff
* pyunits.convert(
stage.A_comp[0, "H2O"],
to_units=pyunits.L
* pyunits.m**-2
* pyunits.bar**-1
* pyunits.hour**-1,
)
** 3
* pyunits.L**-2
* pyunits.m**4
* pyunits.hour**2
* pyunits.bar**3
)
elif AB_tradeoff == ABTradeoff.inequality_constraint:
stage.ABtradeoff = Constraint(
expr=pyunits.convert(
stage.B_comp[0, "NaCl"],
to_units=pyunits.L * pyunits.m**-2 * pyunits.hour**-1,
)
>= m.fs.AB_tradeoff_coeff
* pyunits.convert(
stage.A_comp[0, "H2O"],
to_units=pyunits.L
* pyunits.m**-2
* pyunits.bar**-1
* pyunits.hour**-1,
)
** 3
* pyunits.L**-2
* pyunits.m**4
* pyunits.hour**2
* pyunits.bar**3
)
else:
pass
min_avg_flux = 1 # minimum average water flux [kg/m2-h]
# [kg/m2-s]
min_avg_flux = min_avg_flux / 3600 * pyunits.kg / pyunits.m**2 / pyunits.s
# additional constraints
if water_recovery is not None:
# product mass flow rate fraction of feed [-]
m.fs.water_recovery.fix(water_recovery)
if Cbrine is not None:
# Final brine concentration
m.fs.ROUnits[m.fs.Stages.last()].feed_side.properties[
0, 1
].conc_mass_phase_comp["Liq", "NaCl"].fix(Cbrine)
# add upper bound for permeate concentration
if permeate_quality_limit is not None:
if isinstance(permeate_quality_limit, (int, float)):
m.fs.ROUnits[1].mixed_permeate[0].mass_frac_phase_comp["Liq", "NaCl"].setub(
permeate_quality_limit
)
else:
raise TypeError("permeate_quality_limit must be None, integer, or float")
# ---checking model---
assert_units_consistent(m)
assert_degrees_of_freedom(
m,
4 * m.fs.NumberOfStages
- (1 if (water_recovery is not None) else 0)
- (1 if value(m.fs.NumberOfStages) == 1 else 0),
)
return m
def display_design(m):
print("--decision variables--")
for stage in m.fs.Stages:
print(
"Stage %d operating pressure %.1f bar"
% (stage, m.fs.ROUnits[stage].inlet.pressure[0].value / 1e5)
)
print(
"Stage %d membrane area %.1f m2"
% (stage, m.fs.ROUnits[stage].area.value)
)
print(
"Stage %d water perm. coeff. %.1f LMH/bar"
% (stage, m.fs.ROUnits[stage].A_comp[0, "H2O"].value * (3.6e11))
)
print(
"Stage %d salt perm. coeff. %.1f LMH"
% (stage, m.fs.ROUnits[stage].B_comp[0, "NaCl"].value * (1000.0 * 3600.0))
)
def display_state(m):
print("--------state---------")
def print_state(s, b):
flow_mass = sum(
b.flow_mass_phase_comp[0, "Liq", j].value for j in ["H2O", "NaCl"]
)
mass_frac_ppm = b.flow_mass_phase_comp[0, "Liq", "NaCl"].value / flow_mass * 1e6
pressure_bar = b.pressure[0].value / 1e5
print(
s.ljust(20)
+ ": %.3f kg/s, %.0f ppm, %.1f bar"
% (flow_mass, mass_frac_ppm, pressure_bar)
)
print_state("Feed", m.fs.feed.outlet)
for stage in m.fs.Stages:
print_state(f"Primary Pump {stage} out", m.fs.PrimaryPumps[stage].outlet)
if stage == m.fs.LastStage:
pass
else:
print_state(f"Mixer {stage} recycle", m.fs.Mixers[stage].downstream)
print_state(f"Mixer {stage} out", m.fs.Mixers[stage].outlet)
print_state(f"RO {stage} permeate", m.fs.ROUnits[stage].permeate)
print_state(f"RO {stage} retentate", m.fs.ROUnits[stage].retentate)
wr = m.fs.ROUnits[stage].recovery_vol_phase[0, "Liq"].value
if stage == m.fs.FirstStage:
pass
else:
print_state(f"Booster Pump {stage} out", m.fs.BoosterPumps[stage].outlet)
print_state(f"Disposal", m.fs.disposal.inlet)
print_state(f"Product", m.fs.product.inlet)
def display_system(m):
print("----system metrics----")
feed_flow_mass = sum(
m.fs.feed.flow_mass_phase_comp[0, "Liq", j].value for j in ["H2O", "NaCl"]
)
feed_mass_frac_NaCl = (
m.fs.feed.flow_mass_phase_comp[0, "Liq", "NaCl"].value / feed_flow_mass
)
print("Feed: %.2f kg/s, %.0f ppm" % (feed_flow_mass, feed_mass_frac_NaCl * 1e6))
prod_flow_mass = sum(
m.fs.product.flow_mass_phase_comp[0, "Liq", j].value for j in ["H2O", "NaCl"]
)
prod_mass_frac_NaCl = (
m.fs.product.flow_mass_phase_comp[0, "Liq", "NaCl"].value / prod_flow_mass
)
print("Product: %.3f kg/s, %.0f ppm" % (prod_flow_mass, prod_mass_frac_NaCl * 1e6))
brine_flow_mass = sum(
m.fs.disposal.flow_mass_phase_comp[0, "Liq", j].value for j in ["H2O", "NaCl"]
)
brine_mass_frac_NaCl = (
m.fs.disposal.flow_mass_phase_comp[0, "Liq", "NaCl"].value / brine_flow_mass
)
print("Brine: %.3f kg/s, %.0f ppm" % (brine_flow_mass, brine_mass_frac_NaCl * 1e6))
print("Volumetric water recovery: %.1f%%" % (value(m.fs.water_recovery) * 100))
print(f"Number of Stages: {value(m.fs.NumberOfStages)}")
total_area = value(sum(m.fs.ROUnits[a].area for a in m.fs.Stages))
print(f"Total Membrane Area: {total_area:.2f}")
print(
"Energy Consumption: %.1f kWh/m3"
% value(m.fs.costing.specific_energy_consumption)
)
print("Levelized cost of water: %.2f $/m3" % value(m.fs.costing.LCOW))
print(
f"Primary Pump Capital Cost ($/m3):"
f"{value(m.fs.costing.factor_capital_annualization*sum(m.fs.PrimaryPumps[stage].costing.capital_cost for stage in m.fs.Stages)/ m.fs.costing.annual_water_production)}"
)
print(
f"Booster Pump Capital Cost ($/m3): "
f"{value(m.fs.costing.factor_capital_annualization*sum(m.fs.BoosterPumps[stage].costing.capital_cost for stage in m.fs.LSRRO_Stages) / m.fs.costing.annual_water_production)}"
)
print(
f"ERD Capital Cost ($/m3):"
f"{value(m.fs.costing.factor_capital_annualization*sum(erd.costing.capital_cost for erd in m.fs.EnergyRecoveryDevices.values()) / m.fs.costing.annual_water_production)}"
)
print(
f"Membrane Capital Cost ($/m3): "
f"{value(m.fs.costing.factor_capital_annualization*sum(m.fs.ROUnits[stage].costing.capital_cost for stage in m.fs.Stages) / m.fs.costing.annual_water_production)}"
)
print(
f"Indirect Capital Cost ($/m3): "
f"{value(m.fs.costing.factor_capital_annualization*(m.fs.costing.total_investment_cost - m.fs.costing.total_capital_cost) / m.fs.costing.annual_water_production)}"
)
electricity_cost = value(
m.fs.costing.aggregate_flow_costs["electricity"]
* m.fs.costing.utilization_factor
/ m.fs.costing.annual_water_production
)
print(f"Electricity cost ($/m3): {electricity_cost}")
print("\n")
def display_RO_reports(m):
for stage in m.fs.ROUnits.values():
stage.report()