# WaterTAP Copyright (c) 2021, The Regents of the University of California,
# through Lawrence Berkeley National Laboratory, Oak Ridge National
# Laboratory, National Renewable Energy Laboratory, and National Energy
# Technology Laboratory (subject to receipt of any required approvals from
# the U.S. Dept. of Energy). All rights reserved.
#
# Please see the files COPYRIGHT.md and LICENSE.md for full copyright and license
# information, respectively. These files are also available online at the URL
# "https://github.com/watertap-org/watertap/"
#
###############################################################################
"""
This module contains a zero-order representation of a coagulation/flocculation unit
operation.
"""
from pyomo.environ import Constraint, units as pyunits, Var, Expression
from idaes.core import declare_process_block_class
from watertap.core import build_pt, constant_intensity, ZeroOrderBaseData
# Some more information about this module
__author__ = "Adam Atia"
[docs]@declare_process_block_class("CoagulationFlocculationZO")
class CoagulationFlocculationZOData(ZeroOrderBaseData):
"""
Zero-Order model for a Coagulation/Flocculation unit operation.
"""
CONFIG = ZeroOrderBaseData.CONFIG()
[docs] def build(self):
super().build()
self._tech_type = "coag_and_floc"
build_pt(self)
self.alum_dose = Var(
self.flowsheet().time,
units=pyunits.mg / pyunits.L,
bounds=(0, None),
doc="Dosing rate of alum",
)
self.polymer_dose = Var(
self.flowsheet().time,
units=pyunits.mg / pyunits.L,
bounds=(0, None),
doc="Dosing rate of polymer",
)
self.anion_to_cation_polymer_ratio = Var(
self.flowsheet().time,
bounds=(0, None),
units=pyunits.dimensionless,
doc="Ratio of anionic to cationic polymer in dosage",
)
self.anionic_polymer_dose = Var(
self.flowsheet().config.time,
bounds=(0, None),
units=pyunits.mg / pyunits.L,
doc="Dosing rate of anionic polymer",
)
self.cationic_polymer_dose = Var(
self.flowsheet().config.time,
bounds=(0, None),
units=pyunits.mg / pyunits.L,
doc="Dosing rate of cationic polymer",
)
self.chemical_flow_mass = Var(
self.flowsheet().time,
["alum", "polymer"],
units=pyunits.kg / pyunits.s,
bounds=(0, None),
doc="Mass flow rate of chemical solution",
)
self.rapid_mix_retention_time = Var(
self.flowsheet().config.time,
units=pyunits.seconds,
doc="Rapid Mix Retention Time",
)
self.floc_retention_time = Var(
self.flowsheet().config.time,
units=pyunits.minutes,
doc="Floc Retention Time",
)
self.rapid_mix_basin_vol = Var(
units=pyunits.m**3, doc="Rapid Mix Basin Volume"
)
self.floc_basin_vol = Var(units=pyunits.m**3, doc="Floc Basin Volume")
self.num_rapid_mixers = Var(
units=pyunits.dimensionless, doc="Number of Rapid Mixers"
)
self.num_floc_mixers = Var(
units=pyunits.dimensionless, doc="Number of Floc Mixers"
)
self.num_rapid_mix_processes = Var(
units=pyunits.dimensionless, doc="Number of Rapid Mix Processes"
)
self.num_floc_processes = Var(
units=pyunits.dimensionless, doc="Number of Floc Processes"
)
self.num_coag_processes = Var(
units=pyunits.dimensionless, doc="Number of Coagulation Processes"
)
self.num_floc_injection_processes = Var(
units=pyunits.dimensionless, doc="Number of Floc Injection Processes"
)
self.velocity_gradient_rapid_mix = Var(
self.flowsheet().config.time,
units=pyunits.s**-1,
doc="Rapid Mix Velocity Gradient",
)
self.velocity_gradient_floc = Var(
self.flowsheet().config.time,
units=pyunits.s**-1,
doc="Floc Velocity Gradient",
)
self.power_rapid_mix = Var(
self.flowsheet().config.time,
units=pyunits.kW,
doc="Rapid Mix Power Consumption",
)
self.power_floc = Var(
self.flowsheet().config.time, units=pyunits.kW, doc="Floc Power Consumption"
)
self.electricity = Var(
self.flowsheet().config.time,
units=pyunits.kW,
doc="Total Power Consumption",
)
self._fixed_perf_vars.append(self.alum_dose)
self._fixed_perf_vars.append(self.polymer_dose)
self._fixed_perf_vars.append(self.anion_to_cation_polymer_ratio)
self._fixed_perf_vars.append(self.rapid_mix_retention_time)
self._fixed_perf_vars.append(self.floc_retention_time)
self._fixed_perf_vars.append(self.num_floc_injection_processes)
self._fixed_perf_vars.append(self.num_floc_processes)
self._fixed_perf_vars.append(self.num_rapid_mixers)
self._fixed_perf_vars.append(self.num_coag_processes)
self._fixed_perf_vars.append(self.num_floc_mixers)
self._fixed_perf_vars.append(self.num_rapid_mix_processes)
self._fixed_perf_vars.append(self.velocity_gradient_rapid_mix)
self._fixed_perf_vars.append(self.velocity_gradient_floc)
self._perf_var_dict["Alum Dosage (mg/L)"] = self.alum_dose
self._perf_var_dict["Polymer Dosage (mg/L)"] = self.polymer_dose
self._perf_var_dict["Alum Flow (kg/s)"] = self.chemical_flow_mass[0, "alum"]
self._perf_var_dict["Polymer Flow (kg/s)"] = self.chemical_flow_mass[
0, "polymer"
]
self._perf_var_dict["Rapid Mix Basin Volume (m^3)"] = self.rapid_mix_basin_vol
self._perf_var_dict["Floc Basin Volume (m^3)"] = self.floc_basin_vol
self._perf_var_dict[
"Rapid Mix Retention Time (s)"
] = self.rapid_mix_retention_time
self._perf_var_dict["Floc Retention Time (min)"] = self.floc_retention_time
self._perf_var_dict[
"Rapid Mix Velocity Gradient (1/s)"
] = self.velocity_gradient_rapid_mix
self._perf_var_dict[
"Floc Velocity Gradient (1/s)"
] = self.velocity_gradient_floc
self._perf_var_dict["Rapid Mix Power (kW)"] = self.power_rapid_mix
self._perf_var_dict["Floc Power (kW)"] = self.power_floc
self._perf_var_dict["Total Power Consumption (kW)"] = self.electricity
def rule_rapid_mix_basin_vol(blk):
return (
blk.rapid_mix_basin_vol
== blk.properties[0].flow_vol * blk.rapid_mix_retention_time[0]
)
self.rapid_mix_basin_vol_constraint = Constraint(rule=rule_rapid_mix_basin_vol)
def rule_floc_basin_vol(blk):
return blk.floc_basin_vol == pyunits.convert(
blk.properties[0].flow_vol * blk.floc_retention_time[0],
to_units=pyunits.m**3,
)
self.floc_basin_vol_constraint = Constraint(rule=rule_floc_basin_vol)
def rule_chem_flow(blk, t, j):
if j == "alum":
chemical_dosage = blk.alum_dose[t]
elif j == "polymer":
chemical_dosage = blk.polymer_dose[t]
return blk.chemical_flow_mass[t, j] == pyunits.convert(
chemical_dosage * blk.properties[t].flow_vol,
to_units=pyunits.kg / pyunits.s,
)
self.chemical_flow_constraint = Constraint(
self.flowsheet().time, ["alum", "polymer"], rule=rule_chem_flow
)
def rule_anionic_polymer_dose(blk, t):
return blk.anionic_polymer_dose[t] == blk.anion_to_cation_polymer_ratio[
t
] * blk.polymer_dose[t] / (blk.anion_to_cation_polymer_ratio[t] + 1)
self.anionic_polymer_dose_constraint = Constraint(
self.flowsheet().config.time, rule=rule_anionic_polymer_dose
)
def rule_cationic_polymer_dose(blk, t):
return blk.cationic_polymer_dose[t] == blk.polymer_dose[t] / (
blk.anion_to_cation_polymer_ratio[t] + 1
)
self.cationic_polymer_dose_constraint = Constraint(
self.flowsheet().config.time, rule=rule_cationic_polymer_dose
)
# TODO: WT3 doesn't include pump electricity. Consider adding after case study validation
# pump_electricity(self, self.chemical_flow_vol)
@self.Constraint(
self.flowsheet().time, doc="Constraint for rapid mix power consumption"
)
def rule_power_rapid_mix(b, t):
return b.power_rapid_mix[t] == pyunits.convert(
b.num_rapid_mixers
* b.properties[t].visc_d
* b.rapid_mix_basin_vol
* b.velocity_gradient_rapid_mix[t] ** 2,
to_units=pyunits.kW,
)
@self.Constraint(
self.flowsheet().time, doc="Constraint for floc power consumption"
)
def rule_power_floc(b, t):
return b.power_floc[t] == pyunits.convert(
b.num_floc_mixers
* b.properties[t].visc_d
* b.floc_basin_vol
* b.velocity_gradient_floc[t] ** 2,
to_units=pyunits.kW,
)
@self.Constraint(self.flowsheet().time, doc="Total power consumption")
def electricity_constraint(b, t):
return b.electricity[t] == b.power_floc[t] + b.power_rapid_mix[t]