Anaerobic Digester Costing Method

Costing Method Parameters

The following parameters are constructed for the unit on the FlowsheetCostingBlock (e.g., m.fs.costing.anaerobic_digester) when applying the cost_anaerobic_digester costing method in the watertap_costing_package:

Description

Symbol

Parameter Name

Default Value

Units

Capital cost A parameter \(^1\)

\(A\)

capital_a_parameter

19.3552312e6

\(\text{USD}_{2012}\)

Capital cost B parameter \(^1\)

\(B\)

capital_b_parameter

0.6

\(\text{dimensionless}\)

Reference flow \(^1\)

\(F_r\)

reference_flow

911.054

\(m^3/h\)

Costing Method Variables

There are no costing method variables unique to the anaerobic digester.

Capital Cost Calculations

Capital cost is dependent upon the unit’s volumetric flowrate, \(F\), as shown in the equation below.

\[C_{cap,tot} = A * (F/F_r)^{B}\]

Operating Cost Calculations

Electricity \(C_{elec}\) is a variable operating cost based on the energy intensity \(E\) of the unit process (electricity consumption for the anaerobic digester), electricity price \(P\), electricity flow \(Q\), and the plant utilization factor \(f_{util}\). The annual electricity costs are calculated as:

\[C_{op, tot} = C_{elec} = E Q f_{util} P\]

Code Documentation

References

[1] Eberle, Annika, Irina Tsiryapkina, Steve Peterson, Laura Vimmerstedt, Dylan Hettinger, and Daniel Inman. 2020. An Overview of the Waste-to-Energy System Simulation (WESyS) Model. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-77166. https://www.nrel.gov/docs/fy21osti/77166.pdf.