Energy Recovery Device Costing Method

Costing Method Parameters

The following parameters are constructed for the unit on the FlowsheetCostingBlock (e.g., m.fs.costing.energy_recovery_device) when applying the cost_energy_recovery_device costing method in the watertap_costing_package:

Description

Symbol

Parameter Name

Default Value

Units

Pressure exchanger unit cost

\(C_{PX}\)

pressure_exchanger_cost

535

\(\text{USD}_{2018}\text{/m}^3\text{/hr}\)

Costing Method Variables

The following variables are constructed on the unit block (e.g., m.fs.unit.costing) when applying the cost_energy_recovery_device costing method in the watertap_costing_package:

Description

Symbol

Variable Name

Index

Units

Inlet volumetric flow rate

\(Q_{in}\)

flow_in

[t]

\(\text{m}^3\text{/hr}\)

Capital Cost Calculations

Capital cost is dependent upon the volumetric flow rate, \(Q_{in}\), as shown in the equation below.

\[C_{cap,tot} = C_{PX} * Q_{in}\]

Operating Cost Calculations

Electricity \(C_{elec}\) is a variable operating cost based on the energy intensity \(E\) of the unit process (mechanical work for the ERD), electricity price \(P\), electricity flow \(Q\), and the plant utilization factor \(f_{util}\). The annual electricity costs are calculated as:

\[C_{op, tot} = C_{elec} = E Q f_{util} P\]

Code Documentation