Nanofiltration Costing Method

Costing Method Parameters

The following parameters are constructed for the unit on the FlowsheetCostingBlock (e.g., m.fs.costing.nanofiltration) when applying the cost_nanofiltration costing method in the watertap_costing_package:

Description

Symbol

Parameter Name

Default Value

Units

Membrane replacement factor (fraction of membrane replaced/year)

\(f_{mem,\, replace}\)

factor_membrane_replacement

0.2

\(\text{yr}^{-1}\)

Membrane unit cost

\(C_{mem}\)

membrane_unit_cost

15

\(\text{USD}_{2018}\text{/m}^2\)

Costing Method Variables

The following variables are constructed on the unit block (e.g., m.fs.unit.costing) when applying the cost_nanofiltration costing method in the watertap_costing_package:

Description

Symbol

Variable Name

Index

Units

Membrane area

\(A_{mem}\)

area

None

\(\text{m}^2\)

Capital Cost Calculations

Capital cost is dependent upon the RO membrane area, \(A_{mem}\), as shown in the equations below.

\[C_{cap,tot} = A_{mem} * C_{mem}\]

Operating Cost Calculations

There are no operating costs unique to the nanofiltration unit.

Code Documentation