Osmotically Assisted Reverse Osmosis Costing Method

Costing Method Parameters

The following parameters are constructed for the unit on the FlowsheetCostingBlock (e.g., m.fs.costing.osmotically_assisted_reverse_osmosis) when applying the cost_osmotically_assisted_reverse_osmosis costing method in the watertap_costing_package:

Description

Symbol

Parameter Name

Default Value

Units

Membrane replacement factor

\(f\)

factor_membrane_replacement

0.15

\(\text{dimensionless}\)

Membrane cost

\(C_A\)

membrane_cost

30

\(\text{USD}_{2018}\text{/m}^2\)

High pressure membrane cost

\(C_hA\)

high_pressure_membrane_cost

50

\(\text{USD}_{2018}\text{/m}^2\)

Costing Method Variables

The following variables are used on the unit block (e.g., m.fs.unit.costing) when applying the cost_osmotically_assisted_reverse_osmosis costing method in the watertap_costing_package:

Description

Symbol

Variable Name

Index

Units

Membrane area

\(A\)

area

None

\(\text{m}^2\)

Capital Cost Calculations

There are two classes of OARO costing types (standard and high_pressure), the membrane cost is different with these two methods and the default costing method is standard.

For standard type, the capital cost is defineds as:

\[C_{cap,tot} = C_A * A\]

For high_pressure type, the capital cost is defineds as:

\[C_{cap,tot} = C_hA * A\]

Operating Cost Calculations

The fixed operating cost is correlated to OARO costing types (standard and high_pressure) and the default is standard.

For standard type, the capital cost is defineds as:

\[C_{op,tot} = f * C_A * A\]

For high_pressure type, the capital cost is defineds as:

\[C_{op,example1} = f * C_A * A\]

Code Documentation

References

Bartholomew, T. V., Mey, L., Arena, J. T., Siefert, N. S., & Mauter, M. S. (2017). Osmotically assisted reverse osmosis for high salinity brine treatment. Desalination, 421, 3-11.