Pump Costing Method ==================== Costing Method Parameters +++++++++++++++++++++++++ The following parameters are constructed for the unit on the FlowsheetCostingBlock (e.g., `m.fs.costing.pump`) when applying the `cost_pump` costing method in the ``watertap_costing_package``: .. csv-table:: :header: "Description", "Symbol", "Parameter Name", "Default Value", "Units" "**High-pressure pump**" "Pump unit cost", ":math:`C_{pump}`", "``cost``", "1.908", ":math:`\text{USD}_{2018}\text{/W}`" "**Low-pressure pump**" "Pump unit cost", ":math:`C_{pump}`", "``cost``", "889", ":math:`\text{USD}_{2018}\text{/L/s}`" Costing Method Variables ++++++++++++++++++++++++ The following variables are constructed on the unit block (e.g., m.fs.unit.costing) when applying the `cost_pump` costing method in the ``watertap_costing_package``: .. csv-table:: :header: "Description", "Symbol", "Variable Name", "Index", "Units" "**High-pressure pump**" "Mechanical work", ":math:`W_{mech}`", "``work_mechanical``", "[t]", ":math:`\text{W}`" "**Low-pressure pump**" "Inlet volumetric flow rate", ":math:`Q_{in}`", "``flow_in``", "[t]", ":math:`\text{m}^3\text{/s}`" Capital Cost Calculations +++++++++++++++++++++++++ For the high pressure pump , capital cost is dependent upon the mechanical work, :math:`W_{mech}`, whereas the capital cost of the low pressure pump is based on the volumetric flow rate :math:`Q_{in}`. .. math:: C_{cap,high pressure} = C_{pump} * W_{mech} .. math:: C_{cap,low pressure} = C_{pump} * Q_{in} Operating Cost Calculations +++++++++++++++++++++++++++ Electricity :math:`C_{elec}` is a variable operating cost based on the energy intensity :math:`E` of the unit process (mechanical work for the pump), electricity price :math:`P`, electricity flow :math:`Q`, and the plant utilization factor :math:`f_{util}`. The annual electricity costs are calculated as: .. math:: C_{op, tot} = C_{elec} = E Q f_{util} P Code Documentation ------------------ * :mod:`watertap.costing.unit_models.pump`