Thickener Costing Method ========================= Costing Method Parameters +++++++++++++++++++++++++ The following parameters are constructed for the unit on the FlowsheetCostingBlock (e.g., `m.fs.costing.thickener`) when applying the `cost_thickener` costing method in the ``watertap_costing_package``: .. csv-table:: :header: "Description", "Symbol", "Parameter Name", "Default Value", "Units" "Capital cost A parameter :math:`^1`", ":math:`A`", "``capital_a_parameter``", "4729.8", ":math:`\text{USD}_{2011}\text{/ft}`" "Capital cost B parameter :math:`^1`", ":math:`B`", "``capital_b_parameter``", "37068", ":math:`\text{USD}_{2007}`" Costing Method Variables ++++++++++++++++++++++++ The following variables are constructed on the unit block (e.g., m.fs.unit.costing) when applying the `cost_thickener` costing method in the ``watertap_costing_package``: .. csv-table:: :header: "Description", "Symbol", "Variable Name", "Index", "Units" "Diameter", ":math:`d`", "diameter", "None", ":math:`\text{ft}`" Capital Cost Calculations +++++++++++++++++++++++++ Capital cost is dependent upon the thickener diameter, :math:`d`, as shown in the equations below. .. math:: C_{cap,tot} = A * d + B Operating Cost Calculations +++++++++++++++++++++++++++ Electricity :math:`C_{elec}` is a variable operating cost based on the energy intensity :math:`E` of the unit process (electricity consumption for the thickener), electricity price :math:`P`, electricity flow :math:`Q`, and the plant utilization factor :math:`f_{util}`. The annual electricity costs are calculated as: .. math:: C_{op, tot} = C_{elec} = E Q f_{util} P Code Documentation ------------------ * :mod:`watertap.costing.unit_models.thickener` References ---------- [1] W. McGivney, S. Kawamura, Cost estimating manual for water treatment facilities, John Wiley & Sons, 2008. http://onlinelibrary.wiley.com/book/10.1002/9780470260036.